Industrial Noise & Vibration Centre

+44 1753 698 800

Massive Axial Fan Noise Reduction – at seriously little cost

Steelworks axial extract fan noise attenuation

Low frequency tonal noise (a 112Hz hum) from 8 very large architectural scale axial fans (several stories up that were already fitted with 8m long silencers!) at a Tata steelworks had caused environmental noise problems over a number of years. We diagnosed, we tweaked – and the problem was solved at virtually no cost…

All the possible conventional fan noise control solutions had been considered (largely additional silencers). These would not only have cost a large fortune (and would not have been effective at 112Hz), but they would also have reduced system efficiency and therefore increased the running costs.

Our detailed diagnosis revealed a system resonance that we addressed at source by slowing the fans very slightly. This reducing the fan tones by 20dB at virtually no cost, with no downtime and with no effect on the system efficiency.